Catalog No. SY-GSU-990-345-24-REF
Thermal / campus GSU capability class - ~990 MVA · 345/24 kV
Capability-class GSU shape for large thermal or campus generation blocks. Ratings confirmed on quotation.
32-48 weeks ARO · Target, subject to confirmation.
- IEEE C57
- IEC
- BABA interest
- Interconnect ready
- ISO 9001
- UL
Compliance targets for the quotation. Exact standard parts are confirmed on the RFQ; badges are never presented as live factory certificates.
Core ratings
Nameplate band
990 MVA · 345 / 24 kV · 60 Hz
Listing lead time
32-48 weeks ARO. Target, subject to confirmation.
Market lead-time signal
WoodMac survey via ACP (Q2 2025): GSU avg ~143.4 weeks - survey/IR planning signal, not a Switchyard Supply quote; Nikkei (Mar 2026) quoting Hitachi Energy: waits >30 months - press/interview signal, not a Switchyard Supply quote
Working capital
Interest can be flagged on the quote form. Partner-reviewed, subject to underwriting.
What capability class means
This listing is an RFQ shape drawn from published OEM capability patterns. It is not a named unit for sale, not inventory, and not a reserved factory slot. The reference exists so a buyer planning a very large generation block can start a structured quotation without inventing a spec sheet from scratch.
At this rating the practical questions shift from electrical parameters to feasibility: which factories can build and test the unit, what test-bay and short-circuit capability the FAT requires, and whether the site can even receive the tank.
Single-phase banks versus one three-phase tank
Near 1000 MVA, OEM education describes single-phase banks as a common alternative to a single three-phase tank. Three single-phase units plus a spare cut the transport envelope per piece and give the yard a spares story, in exchange for more pads, more bushings, and more yard bus. The choice belongs to the owner engineer and the study, and the RFQ should state which shape is wanted or ask each OEM to propose.
Haul and FAT dominate this class
DOE's 2024 Large Power Transformer Resilience Report describes LPT shipping weights of roughly 150 to 400 tons, and the largest GSU classes sit at the top of that band. Route surveys, bridge ratings, rail or Schnabel availability, and last-mile SPMT work should be scoped before the PO, not after FAT. GAO reporting in 2023 noted transport alone can run to hundreds of thousands of dollars for some moves.
FAT witness for a unit like this is usually in person for the key dielectric and loss tests. Write the witness rights, the test list per IEEE C57.12.90 or IEC 60076, and the shipping and impact-recorder requirements into the same contract section.
Two clocks on the listing
The catalog ARO band on this reference is a marketplace target subject to confirmation. Market survey clocks for the largest classes run much longer, and EHV or highly custom units have been framed at up to about five years in DOE-linked hydropower addendum reporting. Both clocks are labelled on the listing so planning can use them honestly.
Deep specifications
- Impedance band
- Indicative template - high-MVA thermal GSU %Z often 10-14% band; confirm OEM proposal for capability-class RFQ (NOT a named Hyosung unit for sale)
- BIL class
- Indicative 345 kV class BIL per IEEE C57 - confirm 1050-1300 kV BIL; 24 kV LV class per gen voltage
- Cooling
- ONAF (confirm ODAF for high-MVA thermal). Forced-oil stages and cooler redundancy critical at ~990 MVA class - OEM propose.
- Standards
- IEEE C57 + IEC 60076 dual-path. Capability-class RFQ shape only - ratings confirmed per live one-line.
- Bushings
- HV 345 kV + LV ~24 kV bushings. REF listing = capability class from published OEM delivery pattern - not that serial for sale. Bushing LT may co-gate on HV classes.
- FAT protocol
- Indicative - FAT witness + protocol as draw-gate. REF class does not imply existing factory reservation.
Dual-source OEM paths
- Hyosung HICO Memphis (+ KR) - pursue-order path
- GE Vernova / Prolec (incl. Waukesha lineage) - pursue-order path
Documentation pack
Delivered against the order evidence spine, per line item.
- nameplate / rating plate (capability class until PO)
- FAT protocol + certificate
- %Z band for parallel / interchange
- oil type + processing procedure
- bushing BOM + spare kit plan
- heavy-haul / permit plan (high-MVA haul)
- serial registry + as-built evidence pack
- Incoterms / title-transfer register
Full catalog card · Lead-times guide · FAT guide · Financing