HV breakers / GIS
550 kV dead-tank circuit breaker, 4000 A, 63 kA (reference class, quoted on request)
550 kV class · 4000 A / 63 kA · 60 Hz
About this listing
- 550 kV class, 4000 A / 63 kA. Reference class, quoted on request; no OEM slot, approved-vendor, or inventory claim.
- Ship-to US, Canada. Flatbed / crated. FAT and verified receive available on the quotation.
- Working-capital interest can be flagged on the quotation. Partner-indicated, subject to underwriting. No live APR.
- Compliance targets: IEEE C37, IEC 62271, Interconnect ready, ISO 9001.
Specifications
| Catalog No. | SY-HVBRK-550DT-63 |
|---|---|
| Type | Dead-tank breaker, SF6Verify at quotationInsulation medium and alternative gas confirm per OEM path. |
| kV class | 550 kV |
| Interrupting rating | 63 kAVerify at quotationDuty cycle confirm per RFQ. |
| Continuous current | 4000 A |
| Frequency | 60 Hz |
| Standards | IEEE C37.04 / C37.06; IEC 62271-100 as dual-path option |
| Lead time | 50-100 weeks AROVerify at quotationTarget, subject to confirmation. |
| Ship-to | US, Canada |
| Haul | Flatbed / crated |
| Campus fit | 1 GW+ campus, 500 kV interconnect |
Rows marked Verify at quotation are quoted from class data and locked on the formal quotation, never assumed from this page.
Delivery and compliance
- IEEE C37
- IEC 62271
- Interconnect ready
- ISO 9001
Compliance targets for the quotation. Exact standard parts are confirmed on the RFQ; badges are never presented as live factory certificates.
Order evidence spine
Every award closes these gates in sequence. The same spine appears on your quotation receipt and drives any financing review.
- Entity freezeBuyer-of-record / constructing taxpayer locked for any financing review.
- Slot confirmSupplier-stated production window, once evidence closes.
- FAT passedFactory acceptance test witnessed or document-reviewed.
- Serial recordedNameplate / serial captured against the PO line.
- ShippedUnit cleared the plant or port. Heavy-haul plan attached.
- Verified receiveSite receipt, condition, and serial check.
- Invoice approvedBuyer/EPC approved the OEM invoice (progress-pay path).
Related listings
HV breakers / GIS
145 kV dead-tank circuit breaker, 3000 A, 40 kA (reference class, quoted on request)
- 145 kV class
- 3000 A / 40 kA
- Dead tank
- IEEE C37 / IEC 62271
Request pricing
Quoted on request. Ratings verified at quotation.
Request quotationCatalog No. SY-HVBRK-145DT-40
HV breakers / GIS
145 kV dead-tank circuit breaker, 3000 A, 63 kA (reference class, quoted on request)
- 145 kV class
- 3000 A / 63 kA
- Dead tank
- High fault duty
Request pricing
Quoted on request. Ratings verified at quotation.
Request quotationCatalog No. SY-HVBRK-145DT-63
HV breakers / GIS
170 kV dead-tank circuit breaker, 3000 A, 50 kA (reference class, quoted on request)
- 170 kV class
- 3000 A / 50 kA
- Dead tank
- 161 kV regions
Request pricing
Quoted on request. Ratings verified at quotation.
Request quotationCatalog No. SY-HVBRK-170DT-50